TEADIT® Gasket Solutions for Data Centers
As data centers continue to expand in scale and complexity, TEADIT® leads the industry with advanced sealing technologies that support reliable, energy-efficient infrastructure. Our comprehensive portfolio is engineered to meet the demanding requirements of both next-generation cooling systems and critical power applications, delivering dependable performance in environments where uptime is essential.
From precision sealing solutions for liquid cooling circuits to high-performance products capable of withstanding the extreme temperatures and pressures found in power generation equipment, TEADIT® combines engineering expertise with proven materials technology to address the industry’s most demanding challenges. Every solution is designed to maximize operational reliability, reduce the risk of leakage, and support long service life, helping operators improve efficiency while protecting critical assets.
Explore our application-focused sealing solutions below to identify the ideal TEADIT® gasket for your data center cooling and power generation systems.
Applications
Technology Cooling and Fluid Water Systems
As liquid cooling becomes the preferred approach to supporting AI and high-density computing operations, facility water systems and technology cooling systems will require seals that deliver advanced performance to keep data centers running.
The mechanical design of liquid cooling systems introduces unique sealing requirements. Every connection within a liquid cooling circuit presents a potential leak path, making sealing performance a critical design consideration.
High-density polyethylene (HDPE) piping and lightweight stainless steel manifolds are increasingly specified to reduce installation weight and improve system efficiency, but these components typically have lower flange rigidity and reduced bolt load capacity than traditional piping systems.
Typical Cooling Applications
TEADIT® provides engineered sealing solutions for the critical components that make up modern liquid cooling infrastructure, including:
Designed to withstand continuous thermal cycling, varying pressures, and exposure to water and glycol-based coolants, our gaskets help preserve joint integrity while minimizing the risk of leakage throughout the cooling circuit.
Sealing solutions must therefore achieve leak-tight performance at lower seating stresses, accommodate flange movement, and minimize the risk of distortion. Material selection and gasket design are critical to maintaining joint integrity across these low-load, precision-engineered assemblies.
Recommended TEADIT® Solutions
TEADIT® 24SH
Expanded PTFE gasketing:
TEADIT® NA1035
Compressed fiber gasketing:
Tealon® TF1570
Premium PTFE gasketing:
TEADIT® NA 1081
Compressed fiber gasketing:
Power Generation & Energy Resilience
Beyond thermal management, reliable power generation infrastructure is equally critical to maintaining continuous data center operation. Increasingly, facilities are incorporating on-site generation, microgrids, and standby power systems to improve resilience and support growing computational demands. These assets operate under sustained high temperatures, pressure fluctuations, vibration, and rapid thermal transients that require sealing materials capable of maintaining long-term joint integrity.
TEADIT® provides engineered sealing solutions for power generation equipment, including gas turbines, diesel generators, fuel cells, exhaust systems, piping, and heat recovery applications. Designed for demanding operating conditions, our materials withstand prolonged exposure to elevated temperatures while maintaining sealing performance during both continuous operation and rapid start-up events. As data centers adopt alternative fuels and lower-carbon energy technologies, TEADIT® sealing solutions also support applications involving hydrogen and hydrogen-blended fuel systems, helping ensure reliable operation across evolving power generation infrastructure.
Typical Power Applications
Recommended TEADIT® Solutions
TEADIT® 913M
Premium spiral wound gasket:
TEADIT® 942
High-recovery Kammprofile gasket:
TEADIT® Compression Packing
Low-E packing:
TEADIT® Isolation Kits
Laminated PTFE and additives with fillers:
Lowering PUE Through Better Sealing
Small Leaks Create Big Energy Losses
Power Usage Effectiveness (PUE) remains one of the most important metrics in data center efficiency. Poor sealing can contribute to:
Cooling Losses
Airflow Losses
Reliability Risks
Modern liquid-cooled facilities can achieve PUE values approaching 1.1 when cooling systems operate efficiently. Proper sealing helps maintain system performance and supports lower total operating costs.
Why Sealing Matters
TEADIT® Engineering Support
TEADIT® offers more than just sealing products, delivering comprehensive engineering support and field services to improve joint reliability and long-term equipment performance. Our capabilities include application engineering, gasket design and material selection, flange management support, on-site technical assistance, and custom sealing solutions tailored to specific operating conditions. To provide a complete sealing package, TEADIT® also supplies complementary components, including bolting, hoses, expansion joints, and other critical joint hardware, helping simplify procurement while ensuring system compatibility and dependable performance.